Product Description
Pry mounted heat conduction oil furnace
The pry mounted heat conduction oil furnace is mainly composed of horizontal or vertical heat conduction oil furnaces (fuel, gas, methanol, electric heating or coal), burner, high temperature circulating pump, oil injection pump, high position trough, low position trough, filter, oil gas separator, smoke channel, chimney, high temperature valve, instrument and method. LAN, gaskets, heat transfer oil pipeline system, electrical control and other parts. It is easy to use, flexible and small.
The asphalt mixing station of vehicle mounted heat transfer oil heater and asphalt heating equipment can also be called asphalt concrete mixing plant. A complete set of equipment for batch production of bituminous concrete. According to the way of mixing, it can be divided into intermittent and continuous type. According to the way of transportation, it can be divided into fixed, semi fixed and mobile.
The detailed description of the pry mounted heat conduction oil furnace:
Skid mounted boiler system structure: all equipment is installed on the same prizing seat. Organic heat carrier furnace, combustion machine, chimney, oil storage tank, expansion tank, energy saving device and blower. The energy saving device is one of three air preheaters, steam generators and hot water generators.
Technology: [1] integrated and modular pry mounted structural system is suitable for organic heat carrier furnace.
[2] organic heat carrier furnace is more and more applied because of its notable advantages such as high temperature, no pressure or low pressure.
[3] the traditional organic heat carrier boiler must be installed in the boiler room, and the auxiliary machines are relatively scattered, and the area occupied by the boiler house is correspondingly large. And in order to make the boiler run, there are various pipes, valves and control lines.
The [4] heat conducting oil is driven into the organic heat carrier boiler through the high temperature circulating pump, and is heated by the boiler and then conveyed to the thermal equipment. The temperature regulation system and the temperature stabilization system are configured for the requirement of user's temperature accuracy. The expansion tank plays the role of constant pressure, exhaust, supplementary heat transfer oil and absorption heat expansion in the whole system.
The [5] pry mounted boiler system is equipped with energy saving device. It can make full use of the waste heat of boiler tail gas to reach 1~3 level of national energy consumption grade, and the efficiency of boiler can reach more than 90%. The energy saving device can be configured with steam generators, hot water generators or air preheater according to the needs of users.
In [6] control, the system provides the safety and normal use of the boiler, including the flow of heat, the temperature, the pressure, the flow of fuel, the temperature, the pressure, the tank level, the temperature of the exhaust and the air, the combustion state and so on. It can also provide various monitoring points and running status to DCS and other upper monitoring systems to achieve unattended and remote monitoring and control.
[7] from the installation environment, the skid mounted boiler system only needs to install a concrete bearing boss at the site. There is no need to set up boiler room specially, it can be placed in outdoor or simple canopy. It can prevent rain or dust and design explosion-proof according to user needs. At the same time, it has achieved good results in the plateau area.
[8] installation, all welding is carried out in the original factory, welding quality and accurate installation of components. All components in the factory have passed all kinds of tests stipulated by the state and industry to ensure that all parts are qualified and put into use at the time of leaving factory.
The [9] expansion slot is provided with a overflow pipe, and a partition is set in the oil storage tank. The partition plate separates the oil storage tank into first, second parts, which are lateral and side by side. The lower end of the partition plate is provided with an opening. The overflow pipe of the expansion slot is connected with the first part of the oil storage tank, the second parts of the oil storage tank are connected with the atmosphere, and the oil level in the tank is higher than the opening of the lower end of the partition. The expansion tank does not use the traditional direct air permeability, but uses the storage oil in the tank to play the role of oil seal, thus effectively preventing the direct contact between hot oil and air, and avoiding the oxidative damage of heat conduction oil.
The [10] oil storage tank is provided with oil filling outlet, the expansion slot is equipped with oil filling import, the oil filling and the oil supplement are connected through the oil filling pipe, and the oil filling pump is provided on the oil pipe. The oil storage tank plays a supplementary role in the oil level of the expansion tank. When the oil level of the expansion tank is lower than the designated oil level, the filling pump operates automatically, and the heat transfer oil in the oil storage tank is conveyed to the expansion tank.
[11] has all the functions of the traditional boiler system, and all the equipment, chimneys, control boxes and pipes in the boiler system are installed on the same pry seat.
Illustrating the drawings
[12] organic heat carrier boiler installation layout;
A schematic diagram of the structure of [13] organic heat carrier boiler system;
[14] organic heat carrier boiler system flow chart;
[15] storage tank and its inner partition schematic diagram.
[16] all the equipment is installed on the same pry seat. A pry seat boiler system is formed.
The [17] boiler system is an organic heat carrier boiler system, including organic heat carrier boilers, combustor, chimneys, oil storage tanks, expansion tanks, energy saving devices and blowers.
[18] energy saving device is one of the three parts of air preheater, steam generator and hot water generator.
The [19] pry seat consists mainly of the pry mounting base, the steel frame platform and the ladder. The steel frame platform is located above the pry mounted base, and the bracing base has a supporting frame. The upper end face of the support frame forms a steel frame platform, and the ladder is connected to pry mount the base and the steel frame platform.
The [20] organic heat carrier boiler, the combustor, the chimney, the oil storage tank, the energy saving device and the blower, the hot air duct, the cold air channel and the control box are installed on the base, and the expansion tank is installed on the steel frame platform.
[21] in principle, the skid mounted system has all the functions of the traditional organic heat carrier boiler system. The heat conducting oil is pumped into the organic heat carrier boiler by the circulating pump, and the boiler is heated to transport to the thermal equipment. Requirements for temperature accuracy include temperature regulation system and temperature stabilization system. The expansion tank plays the role of constant pressure, exhaust, supplementary heat transfer oil and absorption heat expansion in the whole system.
The [22] pry mounted boiler system is equipped with energy saving device. It can make full use of the waste heat of boiler tail gas to reach 1~3 level of national energy consumption grade, and the efficiency of boiler can reach more than 90%. The energy saving device can be configured with steam generators, hot water generators or air preheater according to the needs of users.
[23] control, heat conduction oil flow, temperature, pressure; fuel flow, temperature, pressure; tank level; exhaust and air temperature; combustion state and other testing means to ensure the boiler.Safe and normal use. It can also provide various monitoring points and running status to DCS and other upper monitoring systems to achieve unattended and remote monitoring and control.
[24] from the installation environment, we only need to install a concrete bearing boss in the field. There is no need to set up boiler room specially, it can be placed in outdoor or simple canopy. It can prevent rain or dust or design explosion-proof according to user needs. At the same time, it is also used in the plateau area.
The [25] pry mounted boiler system does not need the installation personnel to have a good understanding of the system. It only needs to take the equipment in place according to the instruction and butt each module, connect the heat pipeline, fuel line and power system, and start the commissioning and operation after the heat transfer oil is injected. During the installation process, almost all welding work is carried out in the original factory to ensure welding quality and accurate installation of components.
Website: http://www.tkboiler.com. mailbox: zgtkgl@163.com
Tel: 13526651988 contact: Liu Ben