JCBY

Member Level: Register Member
Enterprise Nature: Private
Operation Mode: Fabricators
Location: Yongjia County Wenzhou City Zhejiang Province China
Authentication Information:

Product Details

QJ well diving

Price 10
Unit
Yield 500/年
Place of Production 龙桥工业区
Product Category 其他
Delivery Time 3-5天

Product Detail Parameters

性能 潜水泵

Product Description

QJ submersible pump motor and pump is direct one water pump into the water to work, it is suitable for deep groundwater, but also can be used for scooping from rivers, reservoirs and canals for water projects: mainly used for irrigation and plateau in the drinking water, but also for the city, factories, mines, railways, the site used for drainage.
QJ submersible pump product features:
QJ submersible pump motor and pump is direct one water pump into the water to work, it is suitable for deep groundwater, but also can be used for scooping from rivers, reservoirs and canals for water projects: mainly used for irrigation and plateau in the drinking water, but also for the city, factories, mines, railways, the site used for drainage.
QJ well submersible pump features:
1, motor, water pump, submerged operation, safe and reliable.
2, the well pipe and pump water pipe without special requirements (i.e.: steel tube wells, tube wells, Doi ash can be used; in the permit, pressure pipe, hose, plastic pipe can be used for lifting pipe use
3, installation, use, maintenance is simple and easy to cover an area of small, do not need to build pumping station.
4, simple structure, saving raw materials.
Submersible pump is used in the right conditions, proper management and service life has a direct relationship.
- QJ submersible pump operating conditions:
1.QJ deep well pump power requirements:
(1) the rated frequency of the centrifugal pump is 50 Hz, and the rated voltage of the motor should be guaranteed to be 380+5% volts of three-phase AC power supply (if the user's voltage is about 660 volts).
(2) the load capacity of the transformer shall not exceed 75% of its capacity.
(3) transformer is far from the well, should consider the transmission line voltage, the motor power is greater than 45KW, requirements of the transformer to the wellhead distance not exceeding 20 meters, more than 20 meters, the transmission line cable specification requirements specifications than the big two grades, and consider the line pressure drop.
2 water quality requirements:
(1) general non corrosive water.
(2) the sand content in water is not more than 0.01% (mass ratio).
(3) pH pH value in the range of 6.5-8.5.
(4) the chlorine ion content in water is not more than 400 mg / L.
(5) hydrogen sulfide content not greater than 1.5 mg / L.
(6) the water temperature is not higher than 20 DEG C.
3 wellbore requirements: