Dyna screw air compressor two stage compression permanent magnet transformer
Price |
11 |
Unit |
个 |
Yield |
111/年 |
Place of Production |
上海 |
Product Category |
石油化工类(换热器、容器、塔器等) |
Delivery Time |
1天 |
|
Product Detail Parameters
Product Description
Two stage compression, permanent magnet inverter air compressor, two stage compression, permanent magnet inverter air compressor, two stage compression, permanent magnet inverter air compressor.
Two stage compression permanent magnet variable frequency air compressor
Power: 7.5-315KW
Air volume: 1.22-66.5m3/min
Exhaust pressure 0.75-1.30MPa
National Service Hotline: 400-900-8509
Immediate consultation
Product details and parameters
De la permanent magnet variable frequency two stage compressor
province
The operation cost is 45% lower than that of the general air compressor.
value
High efficiency, low noise, and durable.
service
24 hours customer service online one hour to respond.
guarantee
German air compressor manufacturer
On power saving
ABOUT POWER SAVING
1. The electricity charge per hour for 250KW single-stage compressor running at full load is about 200 yuan, and the annual electricity charge for 8000 hours is about 1.6 million yuan.
2. If the two-stage air compressor is used, the power consumption can be reduced by more than 10%. The two-stage compressor will save 160,000 yuan per year.
Why is two-stage compression saving power than single stage compression?
1. According to the working principle of the compressor, the isothermal compression type is the most economical. The left is the indicator diagram of the compression process.
2. The diagram shows that 613'4 area (indicated work) is the smallest in the isothermal compression process, but isothermal compression can not be achieved in the actual compression process of the compressor. The power of the first-stage compression is 13'3 area more than that of the isothermal compression, while the power of the first-stage compression saves 2'23''3 area.
Product advantage
PRODUCT ADVANTAGE
1. air compressor mainframe is more efficient.
2. eliminate no-load energy saving
3. eliminate excess pressure and save energy.
4. permanent magnet motor efficiency and energy saving
5. axis drive energy saving
Product details
PRODUCT DETAILS
Two stage compression main screw main engine
Optimize bearing design.
Reduced single machine compression ratio.
Improved volumetric efficiency.
Reduce bearing burdens.
Improve host life.
High efficiency motor
The starting torque is large.
SKF bearings, high efficiency.
The noise is low.
Reduce bearing burdens.
Equipped with refueling device.
No stopping can also be refueling.
Control system
The pressure is constant.
The manipulation is simple.
One shaft transmission efficiency is high.
High cost performance.
High efficiency intake valve
Large caliber, low pressure drop
Improve the stability of the system.
Effective control of control flow.
Cooling system
Fan axial flow, quiet and efficient.
Oil cooled fan, frequency conversion start.
Low power consumption and low noise.
The working principle of two-stage compression is:
_Natural air through the air filter into the first stage of compression, in the compression chamber with a small amount of lubricant mixture, while the mixture of gas compression to inter-stage compression.
The compressed gas enters the cooling channel and contacts with a large number of oil mist, thereby greatly reducing the temperature.
_Cooling compressed gas into the second quarter of the rotor, the second compression, compressed to the final exhaust pressure.
Finally, the compressor is discharged through the exhaust flange to complete the whole compression process.
De Reya Jung magnetic variable frequency double stage compressor
Give you unexpected energy saving experience
01 overall appearance
De Reya Jung magnetic two stage compressor. Beautiful appearance, bright colors, green environmental protection.
The air compressor of a brand is of ordinary appearance, with no obvious features and no aesthetic feeling.
02 energy saving comparison
Dyna combines the permanent magnet frequency conversion with the two-stage compression. The main engine and permanent magnet high efficiency motor are of high efficiency and low energy consumption.
A domestic brand air compressor, or single-stage compression, or permanent magnet frequency conversion, failed to combine the two, low efficiency. The function is incomplete.
03 noise comparison
Dyna two stage compressor. Fan axial flow, oil cooled fan, variable frequency start, low energy consumption, quiet and efficient.
In some domestic ordinary air compressors, the machine is unstable and noisy, which affects the production environment.
Do you want to get an energy saving air compressor free of charge?
SEIZE ENERGY SAVING COMPRESSOR DISPLACEMENT DITECTION PROCESS
Energy consumption test and replacement process for energy saving air compressor
Inspector free energy consumption monitoring
Fill in the check list
The company's approval.
Dyna goes out, delivers, needs.
Unit sign, install, hang meter.
Demand unit fill in application form
(Gai Zhang)
Storage and safety of the company
Assembly preparation
Save the electricity in one week, compare and record.
Energy consumption comparison table
During the probation period (up to a week), transfer the contract or withdraw the machine.
(1) contract transfer (energy management contract), the equipment is free to the buyer, saving electricity tariff.
To apply for purchase