Speaking of live beads, many people's first reaction is eggs. In fact, live beads and eggs are very different. Wool egg is the egg that hatches unsuccessfully, live bead is the egg that hatches normally about 12 days. In terms of taste, live beads taste better than eggs. In terms of nutrition, living beads have higher nutritional value. The water bath type sterilization pot shall be selected for the live bead sterilization pot. The model of sterilization pot depends on the output of customers. There are conventional models of 700, 900, 1000, 1200, two pots and one pot or more pots and one pot.
Classification and selection principle of sterilization pot:
There are four control modes:
1. Manual control type: all valves and water pumps are manually controlled, including water addition, temperature rise, heat preservation, temperature drop and other processes.
2. Electric semi-automatic control type: the pressure is controlled by the electric contact pressure gauge, the temperature is controlled by the sensor (PT100) and the imported temperature controller (the accuracy is ± 1 ℃), and the cooling process is manually operated.
3. Computer semi-automatic control type: PLC and text display are used to process the collected pressure sensor signal and temperature signal, which can store sterilization process, with high control accuracy and temperature control up to ± 1 ℃.
4. Computer automatic control type: the whole process is controlled by PLC and touch screen, which can store the sterilization process. The operator only needs to press the start button. After sterilization, the operator will automatically alarm, and the temperature control accuracy can reach ± 0.5 ℃