Product Description
Intelligent heat exchange unit
Product overview
Uncel smart card is integrated with the heat exchange unit electromechanical equipment heat exchanger, intelligent temperature control device, intelligent electronic control device, a circulating pump, water pump, water tank, fill stabilized condensate tank, filter, instrumentation, sensors, valves and pipes in one, and to the scientific calculation and optimization design, has excellent hardware configuration, reasonable structure, advanced control system, convenient operation and management, has the advantages of saving operating cost, can provide comprehensive solutions for heat integration for the different needs of users, has been widely applied to district heating / cooling system, heat recovery hot water system, cooling system, seawater desalination and other fields.
Two product features
1 using the central control or intelligent temperature controller to control the temperature of the water supply, that is, the water supply temperature can be changed according to the temperature of the outdoor environment, the standard temperature and the time.
According to user requirements to achieve 2 can include computer display, storage to print various operating parameters, heat medium flow, heat medium temperature, heat medium pressure, heating capacity, outdoor temperature, standard room temperature, water temperature, water temperature, water pressure and condensation.
3 when the hot water is heated, the heat exchange section is set up to make full use of the condensed water.
4 water supply system using frequency conversion control, automatic water supply, voltage, and the condensate tank, expansion tank and water tank into one.
5 the use of high-performance corrugated pipe heat exchanger, small unit size, small footprint.
6 standardized module design, according to the user, the flexibility to choose control content, reduce investment.
Three, model description
Four, working principle
In high-temperature water or steam temperature control valve, heating system according to the required flow into the heat exchanger, the heat exchanger with indirect heat exchange mode heating heat users (air conditioning) by heating backwater heating; water flows through the first stainless steel core removal device, the circulating pump into the exchanger is heated for use by the user again. The primary heat medium returns to the primary heating network after the heat exchanger is changed. The water loss of the system is automatically added by the water supply pump according to the set pressure.
Five, installation notes
1 units can be directly placed in the level of indoor concrete foundation (above ground 100mm), fixed with anchor bolt.
2 set the location of the unit must pay attention to the direction of the tube and easy to operate, leaving aside the operating space 500mm.
When the 3 parallel two or more than two sets of units in use, the water outlet pipe of each unit will be installed check valve.
4 when assembled upstairs, just to check the bearing capacity of the floor.
5 and all the units of the unit to take into account the internal interface must be cleaned up before they can take over.
6 before the start of the unit, the hydraulic pressure test must be done according to the design requirements.
Six, model parameters
High efficiency intelligent steam water heating heat exchange unit
Unit type heating
MW heating area
Million square meters of hot water produced
T/h rated steam flow
T/h circulating pump water pump
The number of circulating pump type single power KW type water pump units of single power KW
SYHJQ-N-0.35 0.35 0.515 IRG50-160 (I) B 23 ISG20-160 11.1
SYHJQ-N-0.70 0.7130 IRG50-160 (I) A 24 ISG25-160 11.5
SYHJQ-N-1.05 1.05 1.545 IRG65-160 (I) B 25.5 ISG25-160 11.5
SYHJQ-N-1.40 1.4260 IRG65-160 (I) A 27.5 ISG40-160 12.2
SYHJQ-N-1.75 1.75 2.575 IRG80-160 (I) B 211 ISG40-160 12.2
SYHJQ-N-2.1 2.1390 IRG80-160 (I) A 211 ISG40-160 12.2
SYHJQ-N-2.8 2.84120 4.17 IRG100-160 ISG50-160 23
SYHJQ-N-3.5 3.55150 5.21 IRG125-160A ISG50-160 23
SYHJQ-N-4.2 4.26180 6.25 IRG150-315A ISG50-160 23
SYHJQ-N-4.9 4.97210 7.29 IRG150-315A ISG65-200B 25.5
SYHJQ-N-5.6 5.68240 8.33 IRG200-315 ISG65-200B 25.5
SYHJQ-N-6.3 6.39270 9.37 IRG125-160A ISG65-200B 25.5
SYHJQ-N-7.0 7.010300 10.4 IRG125-160A ISG65-200B 25.5
SYHJQ-N-8.4 8.412360 12.5 IRG150-315A ISG65-200B 25.5
SYHJQ-N-9.8 9.814420 14.6 IRG150-315A ISG65-200B 25.5
SYHJQ-N-11.2 11.216480 16.7 IRG200-315 ISG65-200B 25.5
SYHJQ-N-12.6 12.618540 IRG200-315 (I) B 237 ISG65-200B 25.5
SYHJQ-N-14 142060020.8 IRG200-315 (I) B ISG80-200B 211
SYHJQ-N-17.5 17.52575026 IRG250-315A 255 ISG80-200B 211
SYHJQ-N-21 213090031.2 IRG250-315A 255 ISG80-200B 211
Note: 1, rated condition: water supply temperature of 80 degrees, backwater temperature of 60 DEG C, steam pressure 0.2~0.9Mpa.
2, the maximum water temperature of 95 degrees, backwater temperature of 70 degrees C.
3, steam flow calculated by 0.4MPa saturated steam. Steam pressure and temperature can be adjusted at the same time according to the enthalpy.
High efficiency intelligent water water heating heat exchange unit
Unit type supply
heat
MW heating area
Two times the rated water million square meters
T/h two rated water
T/h circulating pump water pump
The number of circulating pump type single power KW type water pump units of single power KW
SYHJS-N-0.35 0.35 0.515 IRG50-160 (I) B 23 ISG20-160 11.1
SYHJS-N-0.70 0.7130 IRG50-160 (I) A 24 ISG25-160 11.5
SYHJS-N-1.05 1.05 1.545 IRG65-160 (I) B 25.5 ISG25-160 11.5
SYHJS-N-1.40 1.4260 IRG65-160 (I) A 27.5 ISG40-160 12.2
SYHJS-N-1.75 1.75 2.575 IRG80-160 (I) B 211 ISG40-160 12.2
SYHJS-N-2.1 2.1390 IRG80-160 (I) A 211 ISG40-160 12.2
SYHJS-N-2.8 2.84120 68.6 IRG100-160 ISG50-160 23
SYHJS-N-3.5 3.55150 85.7 IRG125-160A ISG50-160 23
SYHJS-N-4.2 4.26180103 IRG150-315A 222 ISG50-160 23
SYHJS-N-4.9 4.97210120 IRG150-315A 222 ISG65-200B 25.5
SYHJS-N-5.6 5.68240137 IRG200-315 230 ISG65-200B 25.5
SYHJS-N-6.3 6.39270154 IRG125-160A 218.5 ISG65-200B 25.5
SYHJS-N-7.0 7.010300171 IRG125-160A 218.5 ISG65-200B 25.5
SYHJS-N-8.4 8.412360206 IRG150-315A 222 ISG65-200B 25.5
SYHJS-N-9.8 9.814420240 IRG150-315A 222 ISG65-200B 25.5
SYHJS-N-11.2 11.216480274 IRG200-315 230 ISG65-200B 25.5
SYHJS-N-12.6 12.618540309 IRG200-315 (I) B ISG65-200B 25.5
SYHJS-N-14 1420600343 IRG200-315 (I) B ISG80-200B 211
SYHJS-N-17.5 17.525750429 IRG250-315A 255 ISG80-200B 211
SYHJS-N-21 2130900514 IRG250-315A 255 ISG80-200B 211
Note: 1, rated conditions: a water temperature 110/75 degrees C, the two water temperature 60/80 C.
2, in the following working conditions of the heating capacity of the unit does not change: (1) a water 130/85 DEG C, the two water 70/95 C. (2) the primary water is 70/95 DEG C, and the water is 55/75 DEG C for two times.
High efficiency intelligent steam water air conditioner heat exchange unit
Unit type heating
MW heating area
Million square meters of heat production
Water
T/h rated steam flow
T/h circulating pump water pump
The number of circulating pump type single power KW type water pump units of single power KW
SYHJQ-K-0.35 0.35 0.530 IRG50-160 (I) A 24 ISG20-160 11.1
SYHJQ-K-0.70 0.7160 1.04 IRG65-160 (I) A ISG25-1601 1.5
syhjq-k-1.05 1.05 1.5 90 1.56 irg80 - 160 (s) 2 11 isg25 - 160 1 1.5
syhjq-k-1.40 1.4 2 120 2.08 irg100 - 160 2 15 isg40 - 160 1 2.2
syhjq-k-1.75 1.75 2.5 150 2.6 irg125 - 160th 2 18.5 isg40 - 160 1 2.2
syhjq - k - 2.1 2.1 3 180 3.12 irg150 - 315a 2 22 isg40 - 160 1 2.2
syhjq - k - 2.8 2.8 4 240 4.17 irg200 - 315 2 30 isg50 - 160 2 3
syhjq - k - 3.5 3.5 5 300 5.21 irg125 - 160th 2 18.5 isg50 - 160 2 3
syhjq - k - 4.2 4.2 6 360 6:25, irg150 - 315a 2 22 isg50 - 160 2 3
syhjq - k - 4.9 4.9 7 420 7.29 irg150 - 315a 2 22 / 2 isg65 - 5.5
syhjq - k - 5.6 5.6 8 480 8.33 irg200 - 315 2 30 / 2 isg65 - 5.5
syhjq - k - 6.3 6.3 9 540 9.37 irg200 - 315 (1) (b) 37 / 2 isg65 - 5.5
syhjq - k - 7.0 7.0 10 600 10.4 irg200 - 315 (1) (b) 37 / 2 isg65 - 5.5
syhjq - k - 8.4 8.4 12 720 12.5 irg200 - 315 (1) 2 / 45 isg65 - 2 tuning
syhjq - k - 9.8 9.8 14 840 14.6 irg200 - 315 (1) 2 / 45 isg65 - 2 tuning
syhjq - k - 11.2 11.2 16 960 16.7 irg250 - 315a 2 55 isg65 - / 2 tuning
syhjq - k - 12.6 12.6 18 1080 18.7 irg250 - 315a 2 55 isg65 - / 2 tuning
syhjq - k - 14 14 20 1200 20.8 irg250 - 315 2 75 isg80 - 11 / 2
注: 1、最高供水温度60℃ (65℃), 回水温度60℃ (55℃), 蒸汽压力0.2 ~ 0.9mpa.
2、蒸汽流量按0.4mpa饱和蒸汽计算.蒸汽压力和温度不同时可按其焓值折算.
高效智能水 - 水空调换热机组
机组型号
供热
量mw 采暖面积
万㎡ 二次额定
水量
t / h 二次额定水量
t / h 循环水泵 补水泵
循环泵型号 台数 单台功率kw 补水泵型号 台数 单台功率kw
syhjq-k-0.35 0.35 0.5 30 0.52 irg50 - 160 (s) 2 4 isg20 - 160 1 1.1
syhjq-k-0.70 0.7 1 60 1.04 irg65 - 160 (s) 2 7.5 isg25 - 160 1 1.5
syhjq-k-1.05 1.05 1.5 90 1.56 irg80 - 160 (s) 2 11 isg25 - 160 1 1.5
syhjq-k-1.40 1.4 2 120 2.08 irg100 - 160 2 15 isg40 - 160 1 2.2
syhjq-k-1.75 1.75 2.5 150 2.6 irg125 - 160th 2 18.5 isg40 - 160 1 2.2
syhjq - k - 2.1 2.1 3 180 3.12 irg150 - 315a 2 22 isg40 - 160 1 2.2
syhjq - k - 2.8 2.8 4 240 4.17 irg200 - 315 2 30 isg50 - 160 2 3
syhjq - k - 3.5 3.5 5 300 5.21 irg125 - 160th 2 18.5 isg50 - 160 2 3
syhjq - k - 4.2 4.2 6 360 144 irg150 - 315a 2 22 isg50 - 160 2 3
syhjq - k - 4.9 4.9 7 420 168 irg150 - 315a 2 22 / 2 isg65 - 5.5
syhjq - k - 5.6 5.6 8 480 192 irg200 - 315 2 30 / 2 isg65 - 5.5
syhjq - k - 6.3 6.3 9 540 216 irg200 - 315 (1) (b) 37 / 2 isg65 - 5.5
syhjq - k - 7.0 7.0 10 600 240 irg200 - 315 (1) (b) 37 / 2 isg65 - 5.5
syhjq - k8.4 8.412720288 IRG200-315 (I) A ISG65-200B 25.5
SYHJQ-K-9.8 9.814840336 IRG200-315 (I) A ISG65-200B 25.5
SYHJQ-K-11.2 11.216960384 IRG250-315A 255 ISG65-200B 25.5
SYHJQ-K-12.6 12.6181080432 IRG250-315A 255 ISG65-200B 25.5
SYHJQ-K-14 14201200480 IRG250-315 275 ISG80-200B 211
Note: 1, rated conditions: a water temperature 95/70 degrees C, the two water temperature 50/60 C